MOTOR ENGINEERING LAB TESTING CAPABILITIES WARREN PLANT

 

A. RANGE AND TYPE

 

 

B.  THE FOLLOWING TYPES OF MOTORS MAY BE TESTED IN THE LAB

 

 

 

THE FOLLOWING IS A LIST OF LAB EQUIPMENT:

Power Supplies:

TRC 0-40 VDC, 300 amps
Magnetics 0-600 VDC, 100 amps
0-300 VDC, 200 amps
0-150 VDC, 400 amps
American 0-120 VAC, 400 amps
0-240 VAC, 360 amps
0-480 VAC, 180 amps
0-600 VAC, 144 amps
0-250 VDC, 600 amps
0-550 VDC, 272 amps
0-750 VDC, 200 amps
W & H 3 phase, 120/208 VAC, 50 Hz, 37.5 KVA
P-W Single Phase 0-300 VAC, 100 amps
P-W 3 Phase, 0-240 VAC, 50 Hz, 4.0 KVA
BK Triple Output 0-30 VDC, 2 amps
0-30 VDC, 2 amps
4-6.5 VDC, 5 amps

Electronic Drives

Altivar 5 var. Speed Drive        3 phase, 480 VAC, 30 HP

Dynamometers

P-W Large Elect. Dyno 100 HP 5000 RPM Max.
P-W Medium Elect. Dyno 30 HP 4000 RPM Max.
P-W Small Elect. Dyno 5 HP 5000 RPM Max.
P-W Small Elect. Dyno 5 HP 5000 RPM Max.
          Belt Drive Adapter 10 HP 10000 RPM Max.
P-W Small Hyd. Dyno
(Used in EMI Room)
7 HP 3500 RPM Max.

 

Hermetic Equipment

Water Circulation Tank with 3 GPM pump.

Inlets and outlets at large, medium and small dynos

 

Environmental

Humidity chamber - 5-95% RH           30-140 Degree F

Size: 36"W x 37"D x 34"H

 

Oven - 550 Degree F.Max.

Size: 22"W x 20"D x 16"H

 

EMI Chamber - Radiated emissions 100 KHz -300MHz

(For preliminary EMI testing only)

Room size: 8'W x 12'D x 7'H

 

Instruments

Electrical and mechanical calibration equipment

Miscellaneous scopes, meters, chart recorders, line analyzers, etc.